Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Huan Jing Ke Xue ; 44(10): 5769-5778, 2023 Oct 08.
Artigo em Chinês | MEDLINE | ID: mdl-37827792

RESUMO

This study aimed to elucidate the cadmium (Cd) concentration and transport characteristics of Pueraria thornsonii in farmland with different Cd pollution degrees, so as to provide a reference basis for phytoremediation of Cd-contaminated farmland. The multi-point experiments in farmland with different Cd pollution degrees[ω(Cd) 0.32-38.08 mg·kg-1] were conducted, and the biomass (dry weight), Cd content, accumulation, concentration, and transport of Cd in P. thornsonii tissues under the main growing period were assessed. According to the results, for P. thornsonii, the tuber dry weight ranged from 5.04 to 11.98 t·hm-2, biomass ranged from 13.21 to 29.07 t·hm-2, and Cd accumulation ranged from 15.74 to 106.03 g·hm-2in the study area. The pattern of Cd uptake by P. thornsonii showed that the main vine>leaf>lateral branches>basal part of sti>tuber. The Cd content in P. thornsonii tissues considerably increased with soil Cd content (P<0.05), whereas the biomass decreased significantly (P<0.05). The Cd concentration and transport factor of aboveground parts in P. thornsonii showed a trend of initially falling, then increasing and decreasing again, whereas the Cd enrichment and transport coefficient of tubers gradually decreased. Correlation analysis revealed that the amount of Cd in the soil was a major predictor of Cd accumulation in P. thornsonii. Under light to moderate Cd contamination, the commercial portion of P. thornsonii (arrowroot)[ω(Cd) 0.03-0.22 mg·kg-1] was less than the standard limit for medicinal plants (≤ 0.30 mg·kg-1). In P. thornsonii from moderately contaminated areas, the Cd concentration and transport factor of aboveground parts were 2.43-7.97 and 3.02-9.81, respectively. This indicates that P. thornsonii is a prospective plant ideal for remediating Cd-contaminated soil because of its high capacity to transfer and enrich Cd.


Assuntos
Pueraria , Poluentes do Solo , Cádmio/análise , Fazendas , Poluentes do Solo/análise , Solo , Biodegradação Ambiental
2.
Opt Express ; 25(19): 22178-22190, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041533

RESUMO

Recently, the single photon avalanche diode optical wireless communication (SPAD OWC) has attracted much attention due to its potential underwater applications. For such system, the channel noise is additive Poisson noise (APN) rather than the commonly encountered additive white Gaussian noise (AWGN) and the corresponding maximum likelihood (ML) detection is hard to provide a useful insight into energy-efficient signal design. By using the previously proposed Hellinger distance design criterion, we design an energy-efficient multi-dimensional constellation within the nonnegative integer set by minimizing the average optical power for a fixed minimum Hellinger distance. Comprehensive simulations indicate that our designed constellation can substantially outperform the currently available pulse amplitude modulation (PAM) and squared PAM for SPAD OWC systems.

3.
Int J Clin Exp Med ; 8(9): 16077-82, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26629115

RESUMO

The aim of this study was to investigate the clinical application effects of a novel computer-aided detection (CAD) system based on three-dimensional computed tomography (CT) images on pulmonary nodule. 98 cases with pulmonary nodule (PN) in our hospital from Jun, 2009 to Jun, 2013 were analysed in this study. All cases underwent PN detection both by the simple spiral CT scan and by the computer-aided system based on 3D CT images, respectively. Postoperative pathological results were considered as the "gold standard", for both two checking methods, the diagnostic accuracies for determining benign and malignant PN were calculated. Under simple spiral CT scan method, 63 cases is malignant, including 50 true positive cases and 13 false positive cases from the "gold standard"; 35 cases is benign, 16 true negative case and 19 false negative cases, the Sensitivity 1 (Se1)=0.725, Specificity1 (Sp1)=0.448, Agreement rate1 (Kappa 1)=0.673, J1 (Youden's index 1)=0.173, LR(+)1=1.616, LR(-)1=0.499. Kappa 1=0.673 between the 0.4 and 0.75, has a moderate consistency. Underwent computer-aided detection (CAD) based on 3D CT method, 67cases is malignant, including 62 true positive cases and 7 false positive cases; 31 cases is benign, 24 true negative case and 7 false negative cases, Sensitivity 2 (Se2)=0.899, Specificity2 (Sp2)=0.828, Agreement rate (Kappa 2)=0.877, J2 (Youden's index 2)=0.727, LR(+)2=5.212, LR(-)2=0.123. Kappa 2=0.877 >0.75, has a good consistency. Computer-aided PN detecting system based on 3D CT images has better clinical application value, and can help doctor carry out early diagnosis of lung disease (such as cancer, etc.) through CT images.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...